Ruskin dampers. Spec vFBD35-818/Replaces VFBD35-708 ©Ruskin August 2018 • 3900 Dr. Ruskin dampers

 
Spec vFBD35-818/Replaces VFBD35-708 ©Ruskin August 2018 • 3900 DrRuskin dampers  Determine the airflow in CFM

Learn more about the FSD60 and its installation. EFL or PFL heat-actuated devices that permit closed closure through the actuator and are automatic remote resettable after test, smoke detection, or power. The FDR25SS is rated for maximum velocity of 2,000 fpm and 4” w. ft. Link Bar 5. 081" thick extruded aluminum at approximately 4" c-c spacing. The damper and sleeve assembly can be installed completely from one side of the wall and does not require mounting angles on the backside. 56 psi and 38. Air control dampers (6 pages) Fire and Smoke Dampers Ruskin TS150 Operation Instructions (2 pages) Summary of Contents for Ruskin DIBD2. C. The TS150 allows the dampers to be reopened after the initial closure for dynamic smoke control. NOTE: Dampers may tolerate higher pressures and velocities than those listed here. MODEL CBDR912 FIBERGLASS ROUND BACKDRAFT DAMPER 3900 Dr. 2. • Airfoil High Performance Dampers • Triple-V Standard Performance Dampers • Ruskin Exclusive True Round Dampers • Ruskin Fast Mounting Angles • Complete Corridor. Combination Fire/Smoke dampers are low leak damper and actuator assemblies that have passed the UL555 and UL555S test requirements. 5 illustrates a plenum mounted damper. Ruskin model ZBBD25 barometric bypass dampers are used to automatically bypass excess air when the duct static pressure increases due to the closing of zone dampers. 0 psi. Each has added features that enable them to meet all high temperature, high pressure airflow. Ruskin Green Products. g. 3. The damper shall be rated for dynamic closure at 2000 fpm (10. From dampers and louvers, to air measuring systems and ERVs, Ruskin ® is recognized for consistent innovation, engineering excellence and precision manufacturing. UL qualifies the damper and its actuator for performance after 30 minute exposure to elevated temperatures. Mounting Angle Fasteners To sleeve #10 bolts or screws, 3/16" (5) steel rivets or 1/2" (13) long welds. Actuators and accessories are factory mounted on the right side when viewed from the actuator side of the wall or floor. Following system stabilization, normal counter-balance operation will continue. In addition, the DC models have. Consult Ruskin or your Ruskin repre-sentative when a damper is to be applied in conditions exceeding recommended maximums. effort to avoid misapplication. Standard features vary by model to. Enter your name and email address Your email address will not be stored by us unless you join our mailing list indicated below on dampers with v-groove blades, we recommend sizing dampers for 1,500 fpm. The factory mounted fast-acting 8-second spring open actuatorprovides optimal performance and reliability. Readily connects to round spiral or flexible ductwork. Ruskin is the industry leader in manufacturing quality, heavy-duty control dampers for industrial applications. Standard, 1 1/2 and 3 hr. Elevated temperature categories begin at 250°F and increase in increments of 100°F. 3. 350° Vertical or Horizontal SIze StAtIC PReSSURe teMPeRAtURe INStALLAtIoN ACtUAtoR ReqUIReMeNtS * UL555S requires that all. The CD82HT Industrial Control Damper has an 8" frame. Available with factory furnished sleeves. Ruskin’s optional wireless damper Inspector™ , utilizing wireless communication protocol by EnOcean®, is the ideal solution for mandatory testing of motorized life safety dampers per NFPA* and Building Code requirements. II. Damper shall be tested and licensed in accordance with AMCA 511 for Air Performance and Air Leakage. We offer a wide variety of products to mee. upstream of the damper. Dampers shall be Ruskin CD60 model. Ruskin Headquarters are located in the Southeastern portion of the Greater Kansas City Metropolitan area Mailing Address: Ruskin Company 3900 Dr. Autodesk®Revit® is Building Information Modeling (BIM) at its best. cheng@jci. Mounting angles must overlap the partition a minimum of 1" (25). Minimum damper size for BD6 with SPC is 12" x 12" (305 x 305). Automatic Balancing Dampers. static pressure. Ruskin® A 0 Page 1 CD60CE Critical Environment High performance 316 stainless steel airfoil blade damper AMCA Class IA Leakage Rated The High-Performing Ruskin Model CD60CE is designed to control and regulate air movement in medium to high velocity and pressure HVAC Systems. Greaves Rd • Kansas City, MO 64030 P: (816) 761-7476 (816) 765-8955 F: E: ruskin@ruskin. max Extremely tight shut-off. Ruskin's Insulating Control Dampers are perfect for performing this task. Replacement Electronic Heat Sensors and Pneumatic Fuse Links for Combination Fire Smoke Dampers. Catalog. With factory furnished actuator, provides fail-safe operation (the damper automatically goes to fail-safe closed position). the following control damper models: CD50 CD504 CD40 CD403 CD51 T-Flange frame is available at additional cost for the following Ruskin commercial control damper models: CD60 CD36 CD356 IL35 CD35 CD355 MINIMUM SIZE Models CD50, CD504, CD60, CD356 and CD355, 6" x 4" (152 x 102). g. Hexagonal axles that ensure a positive lock with blades. Dampers shall be Ruskin Swartwout Series Model 914 FRP control dampers. Ruskin fire/smoke dampers can be rotated or turned over to accommodate the application. Use "Mount With Arrow Up" label as a guide for proper damper orientation. Ruskin fire dampers may be installed using Ruskin FAST angle for one angle installation or Ruskin PFMA for two angle installations. Triple V-groove Blade Airfoil Blade RUSKIN LIFE SAFETY DAMPERS Catalog. For best pressure drop and sound perfor-mance at higher velocities, consider an airfoil blade damper, such as Ruskin model CD60. Masonry Wall or Floor: #10 self-tapping concrete screws Wood/Steel Stud Wall: #10 screws. The FDR25 is rated for maximum velocity of 2,000 fpm and 4” w. Enter your name and email address Your email address will not be stored by us unless you join our mailing list indicated below Ruskin is the industry leader in manufacturing quality, heavy-duty control dampers for industrial applications. primary fire dampers DO NOT provide the necessary protection. Dampers furnished actual size. The High-Performing Ruskin Model CD60CE is designed to control and regulate air movement in medium to high velocity and pressure HVAC Systems. Ruskin CD60DC is rated for airflow in either direction, but Ruskin defines the “front” of the damper as the opposite side of the jackshaft and the “rear” as the jackshaft side. Fire dampers used for the protection of openings in walls, partitions, or masonry floors with fire resistanceThe CFD7T-SB is a UL Classified Ceiling Fire Damper that is UL listed for installation in wood truss floor/ceiling and roof/ceiling designs L528, L546, L558, L574, L585, L586, L592, P533, P545, P548 and H502. at corners of dampers. Fusible Link which is included at no extra charge. Swartwout series model 426 Round Fiberglass Backdraft Damper Molded fiberglass channel with FRP blade stop Designed for corrosive environments Flange mounted Chemical resistant epoxy glue and/or monel fasteners Damper can be installed in both horizontal and vertical airflow directionsAll Ruskin fire smoke dampers meet or exceed the minimum UL555S requirements. The FSDR60 is a "true round" Class 1 leakage rated combination fire and smoke damper designed for use in metal, wood or concrete fire and smoke rated partitions and concrete floors. It features a galvanized steel frame, single skin blades, and a variety of actuator options. g. Pressure limitations shown above allow maximum blade deflection of 1/180 of span on 60" (1524) damper widths. FACE and BYPASS MIXING DAMPERS Dampers larger than maximum single section are an assembly of equal size single section dampers (maximum section size 48"w x 72"h (1219 x 1829) and may be coupled for operation in a variety of ways. 5. RectangulaR DampeRs CD40, CD50, CD60 SerieS DeSCripTiOn The ruskin CD40, CD50, CD60 parallel and opposed-blade HVAC control dampers are custom made-to-order. 1. Ruskin blast suppression dampers have been designed for peak reflective pressures from 1. The critical environment damper series is designed and manufactured with all the necessary features required to withstand the elements of coastal and corrosive applications. Axles that positively lock to blades without screws or welds. Most F/Cs andSMOKE & COMBINATION FIRE SMOKE DAMPER ACTUATORS. When used in fan discharge applications, damper should bethe damper frame. Enter your name and email address Your email address will not be stored by us unless you join our mailing list indicated below Ruskin - Dampers Louvers (816) 761-7476 Subject The FSD35 is a combination fire and smoke damper designed with triple V-groove blades and controlled closure technology that provides point-of-origin fire containment and operational flexibility in static and dynamic smoke management systems. Learn how to select the best damper for your system and achieve optimal air. BIM allows for intelligent, 3D and parametric object-based design and provides full bi-directional associativity. Ruskin smoke damper and actuator assemblies qualify. The FDR25 is rated for maximum velocity of 2,000 fpm and 4” w. Designed to protect life and property, Ruskin® manufactures a complete line of UL classified dampers. Welcome to Ruskin Rooftop Systems 972. (2 kPa). Dampers Corridor Dampers Fire Dampers Smoke Dampers Ruskin® 3900 Dr. MODEL 912 SUGGESTED SPECIFICATION Suggested specification for Model 912 Ruskin Swartwout Fiberglass Series round dampers (revision 6394). 247. It features: Static Ceiling Fire (Radiation) Damper Use in Fire Resistive Floor/Ceiling or Roof/Ceiling Assemblies 165 ֯ F or 212 ֯ F Fusible Link Blade Insulation CSFM 3225-0245:0101. The CD50 was the first AMCA-licensed low leakage damper and bears the AMCA Air Leakage Seal. per sq. Enter your email and join our mailing listDesigned for isolation and containment of the airstream, Ruskin bubble tight industrial dampers for round or rectangular air paths will meet or exceed bubble tight leakage requirements in conformance with AMCA Standard 500D and are available with factory-supplied and mounted actuation. • For proper operation, damper must be installed square and free from. For some applications, it is essential that thermal conductivity be kept at a minimum. Ruskin furnishes, installs, and factory commissions actuators from a diverse lineup of manufacturers offering 2-position, 3-position, or modulating control. SUGGESTED SPECIFICATION • When used in fan discharge applications, damper should be located at least one-half the fan diameter away from the fan. Determine the airflow in CFM. The integral frame and unique “cinch plate” design provides a low cost, high performing damper. It features: Airfoil blades, which have greater strength, less static pressure, superior sealing ability, superior fire protection ability and produce less noise. (Consult Ruskin for detailed CSI MasterFormat Specification. Rectangular Silencers. Ruskin® was founded in the Ruskin Heights area of Kansas City in 1958. MINIMUM SIZE Vertical Installation – 4"w x 4"h (102 x 102). TION 1. 3 (damper installed with duct upstream and downstream). Fire/smoke dampers ordered with pneumatic actuators may be ordered with the EFL and and. DAMPER SIZESRuskin CD60 Commercial Control Dampers Type for a low price! Get free shipping on orders over $999!. The industrial grade backdraft dampers offer rugged construction and heavy gage materials to withstand the high velocities and back. Each has added features that enable them to meet all high temperature, high pressure airflow modulation and shutoff. CDRS82 ROUND CONTROL DAMPER Spec CDRS82-102/Replaces CDRS82-193 ALL STATED SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE OR OBLIGATION. 2) wall thickness with 12 gage (2. appliCaTion CFD7 is the first Ceiling Radiation Damper to be UL listed for steel joist assemblies (L524). It is Leakage Class I classified and features: UL555S Class I. b. • UL555S requires that all combination fire smoke dampers have factory mounted actuators in order to bear the UL label. NOTE:CD355 and CD356 STANDARD CONTROL DAMPERS GALVANIZED STEEL FEATURES Sturdy, steel construction features interlocking frame design. Marketing Literature; Case Studies; White Papers; Engineering Reports; Legacy Literature; Videos; Webinars; Revit® Models; Architectural Gallery; FAQs. After 15 minutes, the damper is closed and reopened. Sun Control Sunshades. Built from strong materials and designed on state-of-the-art equipment, they are perfect for demanding conditions. These UL Classified dampers protect against heat, as well as flame, in ceilings with fire resistance ratings of 3 hours or less. S3G Back Draft Damper Product Data/Submittal Author: Ruskin Authority in Air Control - Subject: Ruskin s S3G Commercial backdraft damper has a 3" (76) frame and is constructed of galvanized steel. Email. 2. Learn more about the features and. a. Horizontal dampers installed in walls and floors shall have extended dynamic closure and operational ratings of 4000 fpm (20. Every damper is built with performance in mind and tested per AMCA standards. Louver Paint Finishes - Color Guide. The CD60SS in 304 stainless steel construction offers corrosion resistance and Class IA leakage performance of 3cfm/ft @ 1" w. The webpage also includes diagrams, dimensions, and performance data of the dampers, as well as installation and maintenance instructions. ©Ruskin 2002 FRAME QTY. Greaves Rd. Each fire damper shall be labeled for use in dynamic systems. c. Ceiling dampers are to be factory installed in a 111/2" (292) tall R6 insulated ductboard box with a 1" (25) turned out flange and 1/2" (13)an AMCA registered laboratory. A. Static pressure and CFM are corrected to . Airfoil blades, which have greater strength, less static pressure, superior sealing. With Seals Dampers 40" (1016) and under – 2 pieces of 18 gage steel. dampers. 125" (3. Leading the industry with innovative designs, Ruskin aluminum airfoil blade dampers are constructed utilizing high yield 6063T6 extruded aluminum frame and blades. Ruskin Control Dampers and Backdraft Dampers Get the air where you want it — when you want it! 3 CD60 Ultra Low Leakage Damper The CD60 damper is a “true” airfoil blade damper designed for medium to high velocity and. SUGGESTED SPECIFICATION 3900 Doctor Greaves Road Grandview, MO 64030 Website: AUTHORITY IN AIR CONTROL. 8) steel. 5 illustrates a plenum mounted damper. Ruskin ® Terms and Conditions for more information. Please refer to the table of contents below to determine where to find complete details on products, pricing, and ordering. dampers. > Case Studies. Dampers shall be in all respects equivalent to Ruskin model CBD6. Multi-section dampers typically use jackshafts to link sections together. com. Grandview, MO 64030 View our location on Google Maps Phone: 816. Dynamic fire dampers shall be Ruskin model DFD60-3. a. Built from strong materials and designed on state-of-the-art equipment, Ruskin Industrial Control Dampers are perfect for demanding conditions. The integral frame and unique “cinch plate” design provides a low cost, high performing damper. a. of 8. Availability: Get a Quote. pressure drop through Ruskin CD/OD102 Dampers. From light duty commercial applications to heavy duty industrial and process applications, Ruskin's comprehensive product portfolio includes high performance quality for every application. Our line of outside air dampers are available in 0% - 35% range or 0% - 100% range, and all are easy to install with factory-provided plugs. (1 kPa) static pressure and shall be tested and rated to close with airflow in either direction. The CD60CE is designed for coastal regions and other corrosive environments such as salt-water regions. It features: Airfoil blades, which have greater strength, produce less sound, greater sealing ability, and static pressure loss. All data has been cor- Dampers 18" (457) and under – 12 gage steel (2. g. 2. per sq. Damper frames Dampers shall be constructed with premium vinyl ester resinsThe FD60 is a UL555 classified, 1-1/2 hour rated, multiblade fire damper. Ruskin is the industry leader in manufacturing quality, heavy-duty control dampers for industrial applications. Dampers shall be in all respects equivalent to Ruskin model CBD2. The EFL closes and locks the damper when temperatures exceed 165°F (74°C)Ruskin FDR25SS is a true round fire damper designed for use in fire rated walls and floors and is the perfect choice when using round duct. Actuators and Damper Accessories. R8039)<o:p></o:p> Static Ceiling Fire (Radiation) Damper Use in Fire Resistive Floor/Ceiling or Roof/Ceiling Assemblies 165 ֯ F or 212 ֯ F Fusible Link Curtain type. Enter your name and email address Your email address will not be stored by us unless you join our mailing list indicated belowThe FSD60V Combination Fire/Smoke Damper is both UL555 and UL555S Classified. Fasteners and Multiple Section Assembly When joining multiple damper assemblies or fastening the damperThe S2SS Backdraft damper has a 2" frame. ©Ruskin 2000 3900 Dr. Ruskin Construction has been intent on developing our marine capacity for two decades with the strategic acquisition of various marine construction companies in. The uick Product Selection Reference Guide assists in selecting the appropriate Ruskin® Product for your application. Our line of outside air dampers are available in 0% - 35% range or 0% - 100% range, and all are easy to install with factory-provided plugs. cealed in the frame. It features: Fire and heat protection where HVAC components penetrate the ceiling membrane. 8955From light operations to heavy-duty industrial applications, Ruskin provides the perfect backdraft damper. Higher temperature ratings available consult Ruskin. It features: Extruded aluminum construction. CDR25 and CDO25 dampers are round and oval volume control dampers. FSD35 FSD36 FSD60 CDO25 CDO25 CD35 CD36 CD50 CD60. Ruskin recommends appropriate bracing to support the damper horizontally at least once for every 8 'of. Greaves Rd. Specifier select damper shall have SPC field-adjustable static-pressure control to maintain pressures in ranges from . Ruskin model TED50XT offers HVAC design engineers an ultra-low leak thermally efficient damper which provides: • Energy savings for building owners • Effective resistance to condensation in climate prone areas. Ruskin’s smoke dampers are UL555S labeled with either electric or pneumatic actuators mounted internal (in air stream) or external (out of air stream). These UL Classified dampers protect against heat, as well as flame, in ceilings with fire resistance ratings of 3 hours or less. We are the leading manufacturer of air and sound. While providing fresh air intake and exhaust, Ruskin Louvers can also provide architectural style to building design. Dynamic fire dampers shall be Ruskin multiple model DFD60. Ruskin Model ZCDR25 can be installed into existing round ductwork. Zone Control. Dampers shall be in all respects equivalent to Ruskin Model CD40. Welcome to Ruskin Rooftop Systems. For best pressure drop and sound perfor-mance at higher velocities, consider an airfoil blade damper, such as Ruskin model CD60. Pressure Relief Doors. Ruskin Literature. The FSD60 is a combination fire and smoke damper that meets UL555 and UL555S standards. a. Industrial Dampers. g. g. 75" w. Zone Control Systems. OPTIONS True Round Fire Damper See model FDR25. Noise Control. Look for the AMCA Labeled products to be sure you are getting the performance you require. Noise Control. The industrial grade backdraft dampers offer rugged construction and heavy gage materials to withstand the high velocities and back. This highly functional “true round” backdraft damper eliminates the need for transitions when flange-mounted to round duct installations and is fitted with a counterbalance assembly that canRuskin May 2020 Page 1 CFD4 Ceiling Fire Damper UL Classified Radiation Dampers. Carbon steel construction. MAXIMUM SIZE Single section Vertical Installation DIBD2 - 32"w x 36"h (813 x 914). 7476 Fax: 816. DAMPER SIZESUnderstanding damper leakage rates and leakage classes enables specifiers, contractors, and building owners to identify the correct damper products. 4 inches w. The Ruskin backdraft damper model CBDR92 is designed to prevent backflow in high velocity HVAC and industrial process systems. The damper/actuator assembly is exposed to elevated temperatures for 30 minutes and then immediately cycled three times. Damper widths from 12" to 60" (305 to 1524) wide shall not leak any greater than 8 cfm sq. Horizontal mount dampers may be installed with the jackshaft above or below the floor. Ruskin "pressure relief" style purge dampers are designed specifically to provide additional make-up air to incineration sys-tems prior to fan start-up. Nailor manufactures a unique and comprehensive line of products essential for a well designed HVAC system. Such applications include isolation of air filtration systems or wherever hazardous duty airflow must be contained. ft. FILES (0) Share this page: Ruskin provides a wide variety of actuators and other accessories to customize our dampers in order to meet your needs. Damper Sleeve Sleeve thickness must be equal to or thicker than the duct con-nected to it. Each fire damper shall be labeled for use in dynamic systems. Grandview, MO 64030 View our location on Google Maps Phone: 816. If the actuator must be mounted on top or bottom, select the FSD60V. Multiple models are intended for diverse heavy duty applications, and can be manually or automatically controlled using factory installed and commissioned actuators. g. It features: Corrosion resistant backdraft protection from its stainless steel construction. II-U438-514/Replaces II-U438-408 ©Ruskin 2014 APPLICATION These installations are for all fire and combination fire and smoke damper installations in cavity shaft wall partitions and apply to the following wall design numbers as detailed in the UL fire Resistance directory: U415, U437, U438, U467, U469 and U497. Conservative ratings are pre-sented intentionally in an effort to avoid misapplication. Ruskin’s smoke dampers are UL555S labeled with either electric or pneumatic actuators mounted internal (in air stream) or external (out of air stream). g. Product• Ruskin FAST Angles • One piece angle shipped with the damper • Available in 1-½" or 2-½" • Metal, wood and masonry walls/floors • Permits damper installation before or after drywall installation • Approved for all Ruskin fire, smoke and fire/smoke dampers LaBOr Saver #2 IntegraL and factOry SLeeveSRuskin® has the largest selections of AMCA certified dampers in the industry. Damper Width “A” Dimension in inches (mm) » Tunnel Fire Dampers DISCLAIMER: The Ruskin® brand’s (hereinafter “Ruskin”) content, functionality and product information provided in this data file, including Ruskin design and dimensions (collectively referred to herein as “Ruskin’s Information”) are offered solely to you as a convenience and are for your information only. Fewer parts, fasteners, and assembly processes ensure years of sustainable performance in heavy duty applications. 2 m/s) and 4” w. UL555S rating up to 350°F (177°C). A 1" (25) diameter jackshaft is normally used. These models combine the strength of stainless steel and the protection of anodized aluminum to combat salt water elements. Learn about the features, specifications and benefits of different series of Ruskin products, such as TDP05K, CD60, CD50, CD40,. 5 Hour for use in 2 Hour Walls. 0) sleeve. a. Deflections in other damper widths (less than 48" [1219]) at Smoke dampers are UL555S tested and labeled, low leak damper and actuator assemblies constructed to restrict the spread of smoke in HVAC systems that are designed to be automatically shut down in the event of a fire, or opened to control the movement of smoke within a building when the HVAC system is part of an engineered smoke control system. Kansas City, MO 64030 (816) 761 -7476 FAX (816) 765 -8955 L = Diameter + 2 inches (51) "D" Diameter 3. The blades are the same thickness throughout the shape, optimizing the R-Value rating. Ruskin model SD50 offers HVAC design engineers an ultra-low leak high performance Leakage Class I smoke damper which provides: • Barrier to stop smoke • Lowest pressure drop for energy savings • Optional fail open operation for smoke exhaust applications • Highest dynamic closure rating of 4,000fpm & 8” static pressure. Ruskin’s adjustable louvers and louver/damper combinations allow our customers to enjoy the benefit of architectural styling with air control and shut off. II. Material thickness shall be equivalent to Ruskin model CDR25 or CDO25 standard construction. • Fire smoke dampers larger than single section may require multiple actuators. Torque applied holding damper closed at 10 in. Ruskin backdraft damper model CBDR82 is designed to open under flow and to prevent back-flow in industrial HVAC or process control systems. ft. for dampers up to 6 sq. It features: 750 degree F standard temperature rating! A variety of applications in air and material volume control systems. • Airfoil blade design for low pressure drop and reduced noise generation. When ordered, as an option, the DTS will beThe DFD60 is a UL555 classified, 1 1/2 hour rated, multiblade fire damper. Consult Ruskin or your Ruskin representative when damper is to be. The CD80AF2 Industrial Control damper has an 8" frame. Face and by-pass arrangement. From light operations to heavy-duty industrial applications, Ruskin provides the perfect backdraft damper. Ruskin. • Kansas City, MO 64030 • (816) 761-7476 • FAX (816) 765-8955 INDUCT MOUNT CONTROL DAMPERS It features: Maximum velocity of 4,000 fpm. Ruskin Literature. 3. It features: AMCA Class 1A leakage for energy savings R value – 2. From our humble beginnings with a handful of employees building fire dampers, Ruskin has grown into the largest and most innovative manufacturer of air control solutions with 29 production and office locations worldwide. g. Ruskin round and oval solutions are perfect for applications utilizing spiral duct, or transitioning from rectangular to round. Ruskin FAST and PFMA are 20 guage steel mounting angles designed and approved for use specifically with Ruskin fire and fire/smoke dampers. The standard location permits the damper to be installed outside the plane of the wall or floor. Triple V-groove Blade Airfoil Blade RUSKIN LIFE SAFETY DAMPERSLeading the industry with innovative designs, Ruskin aluminum airfoil blade dampers are constructed utilizing high yield 6063T6 extruded aluminum frame and blades. for dampers up to 17. Ruskin fire dampers may be installed using Ruskin FAST angle for one angle installation or Ruskin PFMA for two angle installations. The CD60CE in 316 stainless steel construction offers superior corrosion resistance and. specification but their recommendedThe ZMD60 Zone Mixing Damper is suitable for multiple zone applications where high performance is required. Ruskin July 2020 Page1 CD60DC (DATA CENTER) High-performance Galvanized Steel Airfoil Blade Damper AMCA Class IA Leakage Rated The CD60DC is designed for HVAC systems serving data center facilities where high performance and reliability is expected. 765. 5hr Static Fire Dampers » 3hr Static. @ 4" w. Dampers shall be Ruskin Swartwout Series Model CBDR912. Each has added features that enable them to meet all high temperature, high pressure airflow modulation and shutoff. Spec FSDGA-216/Replaces FSDGA-1115 ALL STATED SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE OR OBLIGATION. Built from. 2 and can be equipped with factory-mounted actuators. Learn more about the FSD60 and its installation instructions from this document. Multi-section dampers typically use jackshafts to link sections together. FILES (0) Share this page:Energy Recovery Ventilators. Do not weld or fasten angles together at corners of dampers. Models CD36, CD35, IL35, CD40 and CD403, 4". Speak With a Technical Expert. From light operations to heavy-duty industrial applications and from backdraft control to indoor air quality control, Ruskin provides the perfect control damper. Multiple velocity and temperature points on one or more probes installed in the duct or plenum are averaged to arrive at air measurements. 25" w. Fiberglass Series round backdraft dampers. Axles that positively lock to blades without screws or welds. The unit has encapsulated iris segmented blades and integral air pressure taps for great flow control and validation. 8) galvanized steel struc-Products. Galvanized Steel Airfoil Blades. 5hr Dynamic Fire Dampers » 3hr Dynamic Fire Dampers » 1. Unequal section sizes. 75" w. Masonry/Wall or Floor: #10 self-tapping concrete screws. 350° Horizontal FSD36LP 36"x 14" 4"w. Our History. Damper shall be Ruskin model CDRS82. These designs are also similar to the fire resistance rated ceiling construction described in the International Building Code. For damper styles WR, WC, WO and BC only the duct connection portion extends through the wall and the damper. Dampers shall be in all respects equivalent to Ruskin Model CDRS25. “Out Of Wall” Grille Access Fire Dampers 1 1/2 Hour UL555 Rated | For Dynamic & Static Systems DIBD2GA are dynamic fire dampers designed for “out of wall” applications. Blades have an integral structural reinforcing tube running full length of each blade. The barometric bypass dampers relieve excess air in duct systems through the use of a counter-balanced controlled arm weight. The FSD60FA da mper may be installed. The Damper Test Switch (DTS) is an optional “momentary” push button test switch available on Ruskin fire/smoke dampers. 8955 DIBD20, 40, 60 fire dampers can be installed vertically in walls or horizontally in floors with fire resistance ratings of less than 3 hours. Designed for isolation and containment of the airstream, Ruskin Bubbletight industrial dampers for round and rectangular air paths will meet or exceed bubbletight leakage requirements in conformance with AMCA Standard 500-D Section 8. g. When used in fan discharge applications, damper should be located at least one-half the fan diameter away from the fan. 5 inches (89) Furnish and install, at locations shown on plans or as in accordance with. Enter your name and email address Your email address will not be stored by us unless you join our mailing list indicated belowSun Control Sunshades. A. Rusin anuary 2021 Replaces Spec AIRFLOW-IQ-01 Pae 4 High Performance Ruskin Control Damper Model CD50 • Low Leak, extruded aluminum damper for higher velocity and pressure HVAC systems. The foregoing limited warranty does not apply to (i) consumable products and components (e. (Consult for electronic version of this “Quick” spec as well as for complete 3-part CSI MasterFormat Specifications)Ruskin model ABD offers HVAC design engineers an automatic balancing damper which provides: • Energy savings to building owner • Constant maintained airflow volume • Good indoor air quality • Anti-microbial agent prohibiting bacteria or mold growth • Easy installation; requires no tool for adjustment. Damper bearings shall be of UHMW and mechanically fastened by stainless steel set collars located out of the airstream. DAMPER SIZES Understanding damper leakage rates and leakage classes enables specifiers, contractors, and building owners to identify the correct damper products. NOTES: 1. Smoke dampers utilizing multiple actuators must have all actuators field wired to a common point for simultaneous closure. 765. Caution: Volume Adjust hangs below a rectangular damper 1 1/8”® Furnish and install at locations shown on plans or in accordance with schedules, bubble tight isolation dampers meeting the following specifications. Call (847) 773-0645. Title: CDRS82- Spec Author: Ruskin Created Date:The CFDR7T is UL555C Classified Ceiling Fire Damper for wood construction. It features: UL555S Class I leakage class. TION 1.